Test Code LAB10069 Aspirin Functional Assay
Department
HEMATOLOGY
Collection Requirements
Coveanant HealthCare - DO NOT TRANSPORT VIA TUBE SYSTEM
Must draw a discard tube first.
Must be a full draw.
If a CBC is also ordered, collect the CBC last.
If drawing from a catheter, you must draw at least 5.0 mL of waste prior to drawing the Aspirin specimen.
Primary Collection Container
2 Blue 2.0 mL NaCITRATE (Blue White)
Transport
Whole blood ambient
Preferred Transport Temperature
Ambient
Stability
Ambient: 4 hours
Refrigerated: Unacceptable
Frozen: Unacceptable
Minimum Testing Volume
2.0 mL
Reference Range
Less than 550 Aspirin Reaction Units (ARU) indicates platelet dysfunction consistent with aspirin use.
Methodology
Accumetrics VerifyNow Aspirin Assay
Performed
Sunday – Saturday
Reported
As completed
CPT Codes
85576
Unacceptable Conditions
Hemolysis, clotted specimens, refrigerated or frozen specimen.
Failure to assay within 4 hours of collection.