Sign in →

Test Code LAB10564 Amiodarone

Department

SEND OUTS

Reference Lab Test Number

AMIOD

Refer To

Warde Lab

Primary Collection Container

Red (No Gel)

Alternate Collection Container

Red Microtainer

Transport

Serum refrigerated

Preferred Transport Temperature

Refrigerated

Processing

Centrifuge, separate and send 1.0 mL serum in a screw-capped plastic vial.

Stability

Ambient: 48 hours

Refrigerated: 14 days

Frozen: 14 days

Minimum Testing Volume

0.5 mL

Reference Range

Amiodarone: 1.0–3.0 µg/mL

Desethylamiodarone: 1.0-3.0 µg/mL

Potential Toxic range: >3.0 µg/mL (amiodarone). Therapeutic and toxic effects of desethylamiodarone are not established.

Methodology

High Performance Liquid Chromatography

Performed

Monday, Wednesday, and Friday

Reported

3-4 days

CPT Codes

80299

Unacceptable Conditions

SST

Additional Information

Components:

Includes N-desethylamiodarone