Test Code LAB11282 Beta-2 Glycoprotein 1, IgG, IgM, IgA Antibodies

Department

SEND OUTS

Reference Lab Test Number

B2GAB

Primary Collection Container

Gold (SST)

Transport

Serum Frozen

Preferred Transport Temperature

Frozen

Processing

Centrifuge, separate and send 1.0 mL serum in a screw-capped plastic vial.

Stability

Ambient: 8 hours

Refrigerated: 14 days

Frozen: Undetermined

Minimum Testing Volume

0.5 mL

Reference Range

<7 U/mL Negative 7-10 U/mL Equivocal >10 U/mL Positive

Methodology

Fluorescence Enzyme Immunoassay (FEIA)

Performed

Monday – Friday

Reported

5 days

CPT Codes

86146 x 3

Alternate Collection Container

Lavender 6 mL (K3EDTA)

Unacceptable Conditions