Test Code LAB13009 Cobalt - Serum or Plasma
Department
SEND OUTS
Reference Lab Test Number
COBS
Collection Requirements
Patient Preparation: Patients should be encouraged to discontinue nutritional supplements, vitamins, minerals, and non-essential over-the-counter medications.
Refer To
Primary Collection Container
Trace Metal Serum (No Additive)
Alternate Collection Container
Royal Blue (K2EDTA) Trace Element
Transport
Serum ambient
Preferred Transport Temperature
Ambient
Processing
Centrifuge and separate serum from cells as soon as possible. Send 2.0mL serum in a blue capped ARUP metal-free screw capped plastic vial. Specimens in other containers will be rejected.
Stability
If the specimen is drawn and stored in the appropriate container the trace element values do not change with time.
Minimum Testing Volume
0.5 mL
Reference Range
≤ 1.0 µg/L
Methodology
Quantitative Inductively Coupled Plasma – Mass Spectrometry
Performed
Tuesday and Friday
Reported
4-9 days
CPT Codes
83018
Unacceptable Conditions
SST
Additional Information
Please contact laboratory for metal-free screw-capped plastic vials.