Test Code LAB20874 Cryoglobulin Qualitative
Department
Send Outs
Reference Lab Test Number
CRYGL
Refer To
Collection Requirements
Using a heel warmer to prewarm tube, draw 5.0 mL of blood into a prewarmed (37°C) red top tube. Wrap specimen in heel warmer and send to lab immediately. If collected by Irving, send by stat courier to Houghton lab immediately.
Primary Collection Container
Red (No Gel)
Transport
Serum refrigerated
Preferred Transport Temperature
Refrigerated
Processing
Allow blood to clot in 37°C water bath. Centrifuge at 37°C or ambient temperature. Do not use a refrigerated centrifuge. Keep sample at 37°C until after separation of serum from red blood cells. Send serum in a screw capped plastic vial.
Minimum Testing Volume
2.0 mL
Reference Range
Absent
If a cryoprecipitate is present, a cryocrit (quantitation)
will be performed at no additional charge.
Methodology
Precipitation
Performed
Monday-Friday
Reported
8-11 days
CPT Codes
82595
Unacceptable Conditions
Plasma; Serum separator tube (SST); Grossly hemolyzed or lipemic specimens