Test Code LAB21040 Mitotane, Serum/Plasma
Department
Send Outs
Reference Lab Test Number
MITO
Refer To
Warde Medical LaboratoryPrimary Collection Container
Red Top
Transport
Refrigerated
Processing
Centrifuge, separate serum from cells and send 1.0 mL serum in a screw capped plastic vial.
Stability
Room temperature: 14 days
Refrigerated: 14 days
Frozen: 14 days
Minimum Testing Volume
0.3mL
Methodology
Gas Chromatography (GC)
Performed
Varies
Reported
9-11
CPT Codes
80375
Unacceptable Conditions
Serum separator tube (SST) or Plasma separator tube (PST)