Test Code LAB21049 BRIVARACETAM, SERUM/PLASMA
Department
Send Outs
Reference Lab Test Number
BRIVA
Refer To
Warde Medical LaboratoryPrimary Collection Container
Red top
Alternate Collection Container
Lavender EDTA
Transport
Refrigerated
Processing
Centrifuge, separate serum from cells as soon as possible and send 1.0 mL serum in a screw capped plastic vial.
Stability
Room temperature: 30 days
Refrigerated: 30 days
Frozen: 4 months
Minimum Testing Volume
0.2 mL
Reference Range
See report
Methodology
High Performance Liquid Chromatography/Tandem Mass Spectrometry (LC-MS/MS)
Performed
Varies
Reported
7-11 days
CPT Codes
80375
Unacceptable Conditions
Serum separator tube (SST), Polymer gel separator tube (PST)