Sign in →

Test Code MISC1WARDE39810E Allergen Mahi Mahi IgE

Department

SEND OUTS

Reference Lab Test Number

39810E

Primary Collection Container

Red (No Gel)

Transport

Serum refrigerated

Preferred Transport Temperature

Refrigerated

Processing

Centrifuge and transfer 0.5 mL serum into a transfer tube.

Ship at ambient or frozen temperature Monday through Friday.

Stability

Ambient: 4 weeks

Refrigerated: 4 weeks

Freeze for longer storage.

Minimum Testing Volume

0.5 mL

Reference Range

By Report

Methodology

ImmunoCAP® FEIA

Performed

Monday – Friday

Reported

2-4 Business days

CPT Codes

-86003 (x1)

Unacceptable Conditions

Lipemic samples may lead to rejection.

Additional Information

Testing is forwarded to Viracor Diagnostics by Warde Medical Laboratory.

The ImmunoCAP® FEIA method uses as the solid phase a flexible, hydrophobic cellulosic polymer to which allergen has been covalently linked. The advantage of this system is that it has a very high antigen binding capacity when compared to other systems and it has minimal non-specific binding with high total IgE. Viracor Eurofins provides an optional low range calibrator at 0.1 kU/L and a 0/1 class. This test has been cleared or approved for diagnostic use by the U.S. Food and Drug Administration.