Test Code MISC1WARDEC4AL C4a Level
Department
SEND OUTS
Reference Lab Test Number
C4AL
Collection Requirements
Plasma from a lavender top (EDTA) tube is the only acceptable sample type.
Mix sample thoroughly.
Refer To
Primary Collection Container
Lavender 4 mL (K3EDTA)
Alternate Collection Container
Lavender Microtainer
Transport
Plasma frozen
Preferred Transport Temperature
Frozen
Processing
Centrifuge within 30 minutes of collection and remove cell-free plasma. Send 1.0 mL plasma (0.5 mL minimum) frozen in a screw-capped plastic vial.
Stability
Ambient: Unacceptable
Refrigerated; Unacceptable
Frozen (-70°C): 1 year
Minimum Testing Volume
500 µL
Reference Range
0-2830 ng/mL
Methodology
Radioimmunoassay (RIA)
Performed
1st and 3rd Thursday of the month.
Reported
22-29 days
CPT Codes
-86160
Unacceptable Conditions
Specimens received not frozen.