Test Code MISC2MAYO199PT Carbohydrate Antigen 19-9 (CA 19-9), Peritoneal Fluid
Reporting Name
CA 19-9, Peritoneal FluidUseful For
An adjunct to cytology to differentiate between malignancy-related ascites and benign causes of ascites formation
Performing Laboratory
Mayo Clinic Laboratories in RochesterSpecimen Type
PeritonealSpecimen Required
Patient Preparation: For 12 hours before specimen collection do not take multivitamins or dietary supplements containing biotin (vitamin B7), which is commonly found in hair, skin, and nail supplements and multivitamins.
Container/Tube: Plain, plastic, screw-top tube
Specimen Volume: 2 mL
Specimen Minimum Volume
0.5 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Peritoneal | Frozen (preferred) | 90 days | |
Ambient | 7 days | ||
Refrigerated | 7 days |
Reference Values
An interpretive report will be provided.
Day(s) Performed
Monday through Saturday
Test Classification
This test has been modified from the manufacturer's instructions. Its performance characteristics were determined by Mayo Clinic in a manner consistent with CLIA requirements. This test has not been cleared or approved by the US Food and Drug Administration.CPT Code Information
86301
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
199PT | CA 19-9, Peritoneal Fluid | 50781-4 |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
199PN | CA 19-9, Peritoneal Fluid | 50781-4 |
SITEE | Site | 39111-0 |
Clinical Information
Malignancy accounts for approximately 7% of cases of ascites formation. Malignant disease can cause ascites by various mechanisms, including peritoneal carcinomatosis (53%), massive liver metastasis causing portal hypertension (13%), peritoneal carcinomatosis plus massive liver metastasis (13%), hepatocellular carcinoma plus cirrhosis (7%), and chylous ascites due to lymphoma (7%). The evaluation and diagnosis of malignancy-related ascites is based on the patient clinical history, ascites fluid analysis, and imaging tests.
The overall sensitivity of cytology for the detection of malignancy-related ascites ranges from 58% to 75%. Cytology examination is most successful in patients with ascites related to peritoneal carcinomatosis, as viable malignant cells are exfoliated into the ascitic fluid. However, only approximately 53% of patients with malignancy-related ascites have peritoneal carcinomatosis. Patients with other causes of malignancy-related ascites almost always have a negative cytology.
Carbohydrate antigen 19-9 (CA 19-9) is a modified Lewis(a) blood group antigen. CA 19-9 may be elevated in the serum patients with gastrointestinal malignancies, such as cholangiocarcinoma, pancreatic cancer, or colon cancer. Measurement of CA 19-9 in ascitic fluid is sometimes used in combination with cytology for detecting malignancy-related ascites.
Interpretation
A peritoneal fluid carbohydrate antigen 19-9 (CA 19-9) concentration greater than 32 U/mL is suspicious, but not diagnostic, of a malignancy-related ascites. This clinical decision limit cutoff yielded 44% sensitivity and 93% specificity in a study of 137 patients presenting with ascites. However, ascites caused by malignancies not associated with increase serum CA 19-9 concentrations, including lymphoma, mesothelioma, leukemia, and melanoma, routinely had CA 19-9 concentrations less than 32 U/mL. Therefore, negative results should be interpreted with caution, especially in patients who have or are suspected of having a malignancy not associated with elevated CA 19-9 levels in serum.
Method Description
The instrument used is a Beckman Coulter DXI 800. The Access GI Monitor assay is a 2-site immunoenzymatic sandwich assay. A sample is added to a reaction vessel along with paramagnetic particles coated with polyclonal goat antibiotin antibody, mouse monoclonal biotin conjugate, and buffered protein solution. After incubation in a reaction vessel, separation in a magnetic field, and washing to remove materials not bound to the solid phase, a monoclonal-alkaline phosphatase conjugate is added. After incubation in a reaction vessel, materials bound to the solid phase are held in a magnetic field, while unbound materials are washed away. The chemiluminescent substrate Lumi-Phos 530 is added to the vessel and light generated by the reaction is measured with a luminometer. The light production is directly proportional to the concentration of carbohydrate antigen 19-9 (CA 19-9) in the sample. The amount of analyte in the sample is determined from a stored, multipoint calibration curve.(Package insert: Access GI Monitor Assay, Beckman Coulter, Inc; 2020)
Report Available
1 to 3 daysReject Due To
Gross hemolysis | Reject |
Gross icterus | OK |
Method Name
Immunoenzymatic Assay
Forms
If not ordering electronically, complete, print, and send an Oncology Test Request (T729) with the specimen.